Schneider PowerLogic PM8000 meter via Obvius AcquiSuite EMB A8810 Gateway - Wattics
Book a Demo

Wattics customersDiscover how we can help you drive savings & increase sustainability for your customers or organization

Wattics companyLearn more about who we are, our core values and why our customers choose to partner with us

DATA INTEGRATION

Schneider PowerLogic PM8000 meter via Obvius AcquiSuite EMB A8810 Gateway

PM8000 to Obvius AcquiSuite Data Acquisition Server
Are you ready for energy savings? Enable our cloud-based energy analytics and energy monitoring dashboard for your Schneider PowerLogic PM8000 METSEPM8243 meter via the Obvius AcquiSuite Data Acquisition Server, to discover, measure and verify savings in the premises you manage.

NOTE: It is assumed that your PM8000 METSEPM8243 is already installed. If not, read and understand Schneider manuals for installing, operating, or maintaining your PM8000 METSEPM8243 meters. Installation and program procedures must be carried out and inspected by qualified personnel. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with this product.

 

Step 1: Purchase an Obvius AcquiSuite EMB A8810 Data Acquisition Server

You need to get in touch with Obvius or one of their resellers to purchase an AcquiSuite EMB A8810 Data Acquisition Server. The EMB A8810 will be used to collect data from your PM8000 METSEPM8243 meter and push it to Wattics.

Go to Obvius website

The Obvius team will assist you with the supply and installation of the data acquisition server.

 

Step 2: Retrieve specific information from your Obvius AcquiSuite server

At this stage it is assumed that your Obvius AcquiSuite EMB A8810 Data Acquisition Server is installed and collecting data from your PM8000 METSEPM8243 meter(s).

You must first check the sticker at the back of your Acquisuite Server, and write down the SERIAL NUMBER.

Then, use your browser to connect to the Acquisuite Server configuration webpage (you can find your gateway’s IP address on its display).

  • Click on “Click here for System Configuration”.
  • When prompted to log in, use the default admin/admin credentials (or other if you have modified them).

Acquisuite Server Data Push
 

Select the Modbus/Setup section from the menu on the left.

  • Write down the ACQUISUITE NAME of your gateway. This name may be the same as the serial number, and you may edit it first if you want to give it a name that you can remember more easily.
  • Write down the DATA LOGGING PERIOD of your gateway, which indicates the sampling rate.
  • Make a screenshot/photo of that page (that you will send on to us)

Acquisuite Server Data Push
Click on Modbus/Device List section from the menu on the left.

  • Copy for all the Modbus devices connected to your Acquisuite Server their NAME AND PURPOSE together with their TYPE.
  • Make a screenshot/photo of that page (that you will send on to us)

Acquisuite Server Data Push
 

Click on Modbus/Log File Export section from the menu on the left.

  • Download a comma delimited .csv LOG FILE for one Nexus 1500 meter connected to your Obvius Acquisuite. Wattics already supports the parser for the PM8000 METSEPM8243 meter, but having a copy of the log file format used by your Obvius server will ensure that your setup uses the same configuration.

Acquisuite Server Data Push
 

You should now have with you:

  • Your Acquisuite Server SERIAL NUMBER
  • Your Acquisuite Server DATA LOGGING PERIOD
  • Your Acquisuite Server ACQUISUITE NAME
  • The NAME AND PURPOSE and TYPE of all your PM8000 METSEPM8243 meters connected to your Acquisuite Server
  • A number of .csv LOG FILES for each type of meters connected to your Acquisuite Server
  • Two screenshots of the Modbus>Setup and Modbus>Device List pages

 

Step 3: Register your Acquisuite Server and data points with Wattics

You need to send on the information collected in Step 1:

  • The SERIAL NUMBER of your Acquisuite Servery
  • The DATA LOGGING PERIOD of your Acquisuite Server
  • The ACQUISUITE NAME of your Acquisuite Server
  • Each Modbus device NAME AND PURPOSE
  • Each Modbus device TYPE
  • .csv LOG FILE for each Modbus device TYPE

     
    Upload the screenshots of the Modbus>Setup and Modbus>Device List pages.
     


     

     

     
    Upload a sample log file for all the Modbus devices that have a different Modbus device TYPE, so we can review the log file format.
     

     

     

     

     
    * Mandatory fields


    One of our tech support representatives will confirm your Wattics dashboard account, will set your monthly subscription fee, and will register the Acquisuite Server and your PM8000 METSEPM8243 meter(s) to the dashboard.

    You will then receive a DATA UPLOAD PASSWORD to use in Step 4 when setting up the Acquisuite Server to send log files to Wattics Dashboard.

     

    Step 4: Configure the Acquisuite Server to transmit to Wattics

    You are now ready to set up your Acquisuite Server to send data. Select the Log File Data > Setup/Upload menu.

    Acquisuite Server Data Push
    You must configure your device as follows:

    • Protocol: You must select OBVIUS Building Manager Online (Default)
    • Upload URL: This is the website URL or IP to upload data to. This should be set to https://obvius.wattics.com/
    • Password: This password is used by the Wattics web server to verify the Acquisuite Server device authentication before accepting the uploaded data. You should input the DATA UPLOAD PASSWORD provided to you by Wattics.

    Other features can be set according to your preferences, otherwise leave the default values:

    • Scheduled upload time: This option allows you to control when the Acquisuite Server will initiate the upload process. We recommend that you set an upload time greater than the log cycle, for example 15mn if you log data every 5mn.
    • Number of times to retry: In the event of a failure this option specifies the number of retries to attempt the upload again. If all retries fail, the Acquisuite Server will wait until the next scheduled upload time before trying again.
    • Time to wait before retry: In the event of a failure, the Acquisuite Server can be configured to wait for a specified period of time before attempting another connection. This option specifies how long to wait before retrying.
    • Upload data on alarm status change: This setting will cause the Acquisuite Server to initiate the upload process if any point on any Modbus device enters or leaves an alarm state. This option can be left disabled, unless otherwise instructed.
    • Upload data on low disk alarm: This feature will cause the Acquisuite Server to attempt a data upload immediately if the log file storage area is more than 75% full. This option can be enabled, unless otherwise instructed.
    • Allow remote Modbus device configuration: This feature is not supported by Wattics and can be left disabled, unless otherwise instructed.

     

    Step 5: Start data upload

    Click Apply and then the Upload Data Now button on the right to start data upload.

    Acquisuite Server Data Push
     

    Your data will be sent to Wattics, log in to your dashboard and get started!

    PM8000 METSEPM8243 Data Push

    Schneider Integrations

    Schneider TAC Xenta 411 via Octopus Gateway

    Schneider PowerLogic EGX300 Gateway via FTP

    Schneider PowerLogic PM8000 meter via Obvius AcquiSuite EMB A8810 Gateway

    Schneider Com’X 510 via FTP

    Create your own integration

    Not supported yet? Don’t be left behind and integrate now

    Go to the page

    Energy & Air Analytics Dashboard

    Learn more about the analytics tools in the Wattics platform to analyse energy and air quality performance in your facilities

    Check features

    Subscribe to our blog

    Sign up to keep up-to-date with what’s happening within the industry

    Subscribe